HEATER AND THERMOSTAT
B-93-YTC1KL Thermostat YTC-1KL
Features
Compliant with international standard (IEC) :
Designed to be compliant with international standard (IEC standard) and bears CE marking. Can also be used in countries other than Japan.
Heater abnormality detection function :
It constantly monitors the value of the current flowing through the heater and shuts of f the output immediately if something goes wrong. Abnormalities to be detected:
(1) Temperature sensor or liquid level sensor is not connected or abnormal
(2) When the temperature does not rise even when energized for a certain period of time
(3) When leakage is detected
(4) When the resistance value of the heater changes significantly
(5) When heaters which exceed rated output are connected
(6) When temperature of heater rised too much (in case YTC-1KL is connected to thermal fuse) (Heaters for YTC300 equip thermal fuse)
Supports worldwide input voltage :
It is possible to use a small heater that fits in a small-capacity tank even though the input voltage is worldwide.
Specifications
Rating | 100-240V±10% 50/60Hz 1KVA |
Rating Output | AC100-240V, 1KW |
Setting Range | 0~100℃、Resolution 0.1℃ |
Temperature Sensor | Pt100,PTFE |
Standards | Safety: IEC61010-1 EMC:EN61326-1 FCC Part15 Subpart B |
Heater | AC100-240V、50-1000W |